Guangzhou Kai Yuan Water Treatment Equipment Co., Ltd.

Guangzhou Kai Yuan Water Treatment Equipment Co., Ltd. Guidelines:1.tell us the raw water;2.required production capacity;3.what's the pure water used for? Email: gzky01@kywater12.com; whatsApp/wechat

Manufacturer from China
Active Member
7 Years
Home / Products / Seawater Desalination System /

2000LPD Salt Desalination System Seawater Reverse Osmosis Plant

Contact Now
Guangzhou Kai Yuan Water Treatment Equipment Co., Ltd.
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MissAndrea Xu
Contact Now

2000LPD Salt Desalination System Seawater Reverse Osmosis Plant

Ask Latest Price
Brand Name :Kaiyuan
Model Number :KYRO-2000LPD
Certification :ISO9001, CE, SGS
Place of Origin :Guangzhou, China
MOQ :negotiation
Price :negotiation
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :>300sets/month
Delivery Time :1-7working days(depand on raw materials stocking)
Packaging Details :export standard wooden case(plywood), no need to fumigate, suitable for shipping.
Name :Seawater Desalination System
Production Capacity :2000liters per day
Pipe fitting :U-PVC
Warranty :1 Year
Size :700x700x1500MM
Weight :350KG
Feed Water TDS :<35000mg/L
Desalination Rate :99%
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Seawater Salt Desalination System RO Drinking Water Plant 2000LPD

Reverse osmosis process uses semi permeable spiral wound membranes to separate and remove dissolved solids,organic, pyrogens, sub micron colloidal matter and bacteria from water. Feed water isdelivered under a pressure of approximately 16 kg/cm2 through reverse osmosis membranes. Waterpermeates the minute pores of the membrane and is delivered as purified water. Impurities in the water are concentrated in the reject stream and flushed to drain. Reverse osmosis is capable of removing 90-99% of total dissolved solids (TDS), 99% of organic, including pyrogens, and 99%bacterials in the feed water.

*Raw water: Seawater TDS more than 20000ppm.

*Capacity;1000GPD or according to customer's requirements.

*Output water application: WHO Drinking water standard........or according to customer's requirements.

Parameters of 2000LPD RO Seawater Purifier
Product Name
Material
Brand
Usage
Raw Water Pump
Fluoroplastic seawater corrosion -resistance
CNP
Provide needed pressure for every pre-treatment filter
Sand Filter
FRP
China
Remove the water contains sediment, manganese, rust, colloid material, and other particles in the above 20UM of substances hazardous to health.
Anti-dosing system
U-PVC
Italy(SEKO)
To prevent the ro membrane blocking easily.
Security Filter
U-PVC
China
Remove fine particles, sand filters can remove very small colloidal particles in the water, so that the turbidity reached 1 degree.
High Pressure Pump
SUS-316
Danfoss
Provide needed pressure for RO system
RO Membrane
SW30HRLE-4040
USA,Dupont
Can remove particles, colloids, organic impurities, heavy metal ions, bacteria, virus, heat source etc. harmful substances and 97% dissolved salts.
UV Sterilizer /Ozone generator
14W / 3G
China
Kill bacterial in water. UV for direct drinking water. Ozone generator for bottle water

Main Features :

1.Can run and produce water continuously, highly automatic

2.No need chemical to regeneration,easy operation and maintainance
3.RO system uses imported USA DOW membrane
4.Automatic switch on when lack of water,and switch off when no water or full of water
5.RO membrane auto wash and reduce the pollution speed.
6.Low-pressure switch protects high-pressure pump from damage cause by water supply stops.
7.Production water conductivity meter monitors water quality online continously.
8.Input water and dense water pressure meters, monitor the RO differential pressure and remind the time of washing.


Seawater Desalination System Consumable items:

There are several kinds of consumables you need to replace regularly.
a. Quartz sand: replaced about every 15 months. 50kg/bag
b. Activated carbon: replaced about every 15 months. 25kg/bag
c. Resin: replaced about every 15 months. 25L/bag
d. PP Filter cartridge: replaced about every 1 month.
e. Ro membrane: replaced about every 2 year.
We suggest you buy 1- 2 years of PP filter cartridges together with machine. Because these PP filter cartridges need to replace every month.

2000LPD Salt Desalination System Seawater Reverse Osmosis Plant


Some parts function:


1. Raw water pump: provide needed pressure for every pre-treatment filter;
2. Quartz sand filter: use fiber glass as housing, fill quartz sand, it can filter big particles impurities, suspended substances, colloids etc. Important to remove iron and sediments you mentioned;^^
3. Antiscalant system: (It is recommended to add H2SO4 to adjust the pH value to avoid CaCO3 precipitation and reduce seawater desalination membrane fouling---cost-effective and no side-effect)
4. Security filter: prevent large particles, bacteria, viruses into RO membrane, accuracy is 5µm;


Seawater Desalination System Photos:
2000LPD Salt Desalination System Seawater Reverse Osmosis Plant

2000LPD Salt Desalination System Seawater Reverse Osmosis Plant

Thank you so much for your value time. Any questions please send us inquiry or chat now!

We will reply you within 24hours. Whatsapp/ wechat/ tell: +86 13711203110


Guidelines for getting a proper quotation
Tell us the raw water/source of water
Provide water analysis report
Required production capacity( 500 liters per hour, 1000liters per hour…)
What's the pure water used for( drinking, bottle water or industrial use…)

Inquiry Cart 0