15TPH Mechannial Iron Manganese Removal Filter Waste Water Treatment

Ask Latest Price
Brand Name :Kaiyuan
Model Number :KYRO-15TPH
Certification :ISO9001, CE, SGS
Place of Origin :Guangzhou, China
MOQ :>= 1sets
Price :negotiation
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :>300sets/month
Delivery Time :30working days(depand on raw materials stocking)
Packaging Details :export standard wooden case(plywood), no need to fumigate, suitable for shipping.
Name :Iron Manganese Removal Filter 15TPH
Preatment filter :Quartz sand/ activated carbon/ manganese sand/ PP
Optional :PLC touch screen/ Regulating wheels/ Two-stage RO system
Tank materials :Fiber glass/ Stainless Steel/ Carbon Steel
Voltage :220V/ 380V/ 415V, 50Hz/ 60Hz, 3ph
Production Capacity :15000Liters per houw
Pipe fitting :SUS304/ SUS316 /U-PVC
Application :Water purifying
Tank size :Φ1800×2600MM
Warranty :1year
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Waste Water Treatment /Mechannial Filter /Iron Manganese Removal Filter 15TPH

Why do you need a iron manganese removal ?

The majority of the water extracted from the deep wells will carry mud, particulate matter, odor, can not be used directly, we do a good understanding of the well water in rural areas, the fundamental solution to the problem of the smell of water, the use of well water filter to Family a healthy environment. Mainly is to remove the iron and manganese ions in water.

How it works:

Fe (Mn) of groundwater through aeration or adding an oxidizing agent, the water iron (manganese) ions begin oxidized manganese sand filter when the water flows through when contact occurs during filtration and the filter surface oxidation biochemical and physical adsorption interception , so that the water iron (manganese) ions precipitate removed. Especially in the treatment of micro process polluted groundwater manganese, iron, manganese bacteria not only can effectively remove, while ammonia as a nutrient source to the water for metabolism, the participation of the other bacteria, and to achieve the effect of ammonia.

Principle:

4Fe2++O2+10H2O 4Fe(OH)3+8H
2Mn2++O2+2H2O 2MnO2+4H+

Pretreatment of this system

1.Raw water pump: provide pressure for pretreatment filter

2.Quartz sand filter: filtration the big particle in the source/well/underground water, and make water more clearer

3.Activated carbon filter: remove chlorine,colour,metallic,smell in the water after sand filter.

4.Manganese sand filter: remove iron and manganese ions in water.

5.Security filter: 5um filtration function, remoce the volume larger than 5um from water.

Filters flushing control hand can be optional(manual/automatic)

Security and ro part:

1.High pressure pump

2.RO membrane housing/vessel

3.RO membranes: remove more than 97% dissolved ions(salt,ca2+,Mg2+,metallic,corrosive ions... ) and bateria,virus...

4.UV/ozone: For powerful bateria killing

5.Electronic system:PLC touch screen or normal panel for optional

Consumbles details for this system:

1.Quartz sand:should be replaced every about 15 month

2.Activated carbon:should be replaced every about 15 month

3.pp filter cartridge:should be replaced every 1 month

4.ro membranes:should be replaced every about 24 month

Suitable for outside requirement:

1. Raw water can be well water,city water,river/lake water:TDS 2000 ppm, Inlet water flow rate≥30.0 m3/h

2. System desalination rate≥97%, recovery rate≥50%

3. Maximum working pressure:2.0MPa

4. Electriciy:380V/3 phases/50 or 60Hz Power consumption=25Kw

Output treated water usage: To provide the clean,health water for community/villager water supply or commercial bottled water for selling ...

1.For residential drinking,cooking water.

2.For commercial bottle pure drinking water.

3.For agricultural irrigating and drinking water.

4.Electric mental costing industry

5.Pharmaceutical industrial water

15TPH Mechannial Iron Manganese Removal Filter Waste Water Treatment

15TPH Mechannial Iron Manganese Removal Filter Waste Water Treatment

15TPH Mechannial Iron Manganese Removal Filter Waste Water Treatment

15TPH Mechannial Iron Manganese Removal Filter Waste Water Treatment

15TPH Mechannial Iron Manganese Removal Filter Waste Water Treatment

Thank you so much for your value time.Any questions please click "contact now" send us inquiry !We will reply you within 24 hours. Tel/whatsapp/wechat: +86-13660858152
Guidelines for getting a proper quotation
Tell us the raw water/source of water
Provide water analysis report
Required production capacity( 500 liters per hour, 1000liters per hour…)
What's the pure water used for( drinking, bottle water or industrial use…)
Inquiry Cart 0